Watch our videos on this channel to learn the most advanced and skillful ways of diagnosing and repairing many types of Printed Circuit Boards (PCB). We use many types of advance tools to troubleshoot and fixing the problem. We also provide videos on Industrial, Commercial & Domestic Refrigeration Systems and Air Conditioning. Please Subscribe to our channel to stay updated and to keep learning. Thank you for Visiting our channel. Please don't forget to Subscribe, Share and like :) if you have any questions, please feel free to contact on +92 333 8921850
#code repair # inverter ac PCB course #review for ac repairing course #ACPCBrepairingcourse #AC PCB training institute #ACPCBrepairing #ac PCB repairing course in Pakistan #ac PCB repair #Repair ac #PCB #repair ac PCB repairing #BestACPCB repairing #ACrepairing course# best ac PCB repairing # inverter ac PCB repair and voltage study # ac PCB board repair # How to repair inverter ac PCB board # ac PCB repair Kaise kara# inverter ac PCB online course # inverter ac PCB repairing institute # inverter ac indoor PCB wiring # Haier washing machine PCB repair # online inverter repairing course# circuit repair training # inverter operation in power electronics #Basic electronics channel #inverter fridge PCB repair #washingmachinePCBrepaircourse# inverter circuit board #ac repairing training center #AC Godraj inverter AC #Ustad #Babar #BabarPCB #Babarelectronics #Haier inverter ac New model inverter PCB#DC inverter Haier outdoor PCB #Haier inverter ac old model inverter PCB# Haier indoor PCB # E1# E2# E3# E4# E5# E6# E7# E8# E9# EE# EH# F1# F2# F3# F4# F5# F6 #F7 #F8 #F9 #FO #FU #PO #P1 #P4 #P7#PH #H5 #OB #U8 #EE #EH #F1 #F21 #F24 #F25 #F28 #H5 #Samsung #E121 #E122 #E468 #E485 #Panasonicerror #H15 #H27 #H30 #Dawlance #C4 #mamunkanjan #electronics #inverter Washing machine PCB repair #Washing machine PCB Diagram #Gree Dc Dawlance PEL Orient Dc inverter ac P4 error code outdoor pcb Dc inverter ac PCB PEL #Dawlance Orient Kenwood #Changhong PEL Orient# Dawlance Kenwood Haier Dc inverter ac E7 error code outdoor pcb TCL DC inverter ac EE P4 P6 P8 error code Gree Dc Gree Dc inverter ac E6 error code outdoor pcb Dc Gree Dc inverter ac E6 error code outdoor pcb Dc Changhong Ruba Dc inverter ac E5 error code VRF PCB repairing center Babar ElectronicsDawlance Dc inverter ac F1 error code outdoor pcb Dc inverter ac error code repair Sir BabarChanghong Ruba Dc inverter ac J5 error code Electrolux Dc inverter ac J5 error code outdoor pcb Dawlance Dc inverter ac P4 error code outdoor pcb Dc inverter ac service center sir Babar Kenwood Dc inverter ac FO error code outdoor pcb inverter ac pcb teacher Sir BabarHaier Dc inverter ac 1 ton /1.5 ton /2 ton PCB connection VRV / VRF PCB repairing center Sir BabarHaier Dc inverter ac compressor off in one minute No error IPM kya hai IPM Testing Sir Babar Gree DC inverter ac outdoor pcb E8 error code and indoor pcb Orient Dc inverter ac outdoor pcb P4 error
Transcript
00:00Assalam-o-Alaikum.
00:02This is the 15th error.
00:04It comes in the convert and
00:06removes itself.
00:08There are a few reasons for this.
00:10There are faults.
00:12The main thing is that
00:14this red colored
00:16jack is here.
00:18It is red here.
00:20If here it is
00:22that if in this
00:24due to some reason
00:26it gets disconnected because
00:28there is a problem.
00:30There is an overload
00:32inside it.
00:34It is taped.
00:36I saw a video
00:38that there is a gas in it.
00:40There is no gas in it.
00:42There is nothing.
00:44There is only a leaf.
00:46We can turn it off when it is hot
00:48and turn it on when it is hot
00:50at the same temperature.
00:52If we flip the leaf inside
00:54and fit it upside down,
00:56it starts the opposite work.
00:58That is later.
01:00If there is a fault in it,
01:02the continuity should be 0.
01:04The continuity should be
01:060.
01:08There should be
01:10no resistance in it.
01:12If this problem comes again
01:14and again,
01:16you can check
01:18that due to some reason
01:20the compressor is overheating.
01:22If there is a blackage in the compressor
01:24then also the compressor will overheat.
01:26If there is a function valve,
01:28it is not working.
01:30If there is a capillary tube,
01:32it is not working.
01:34Due to these reasons,
01:36you will see
01:38error 15.
01:40You can check all these things
01:42in detail.
01:44If the heat sinker gets dirty,
01:46then also error 15
01:48starts coming.
01:50Check all these things.
01:52If due to some reason
01:54the compressor is overheating,
01:56then also error 15
01:58starts coming.
02:00These are the small things
02:02which I have tried to tell you.
02:04Watch our video completely.